Our desktop test bench is equipped to test units with a power capacity upwards to a maximum of about 3kW. This robust capability allows us to support a broad spectrum of desktop units, offering comprehensive testing for a variety of models and specifications to meet diverse testing needs.

Input Line Impedance Stabilization Network (LISN) Rating Limitation:
The LISN is single-phase and is rated for 20A.

  • At 115V, the LISN can support up to approximately 2.3kW.
  • At 230V, the capacity increases to about 4.6kW.

Load Bank Power Limitations:
The diagram below Q19 includes a table of the power limitations of each load bank we have available. These limitations are essential to consider when configuring your tests to ensure that the load banks can adequately support the power requirements of the server units being tested.