Where do you measure the output voltage?

To accurately measure output voltage for desktop power supplies tested at both 115V and 230V EU input, we connect sense leads from the Chroma 63640-150-60 and 63610-80-20 electronic load banks directly to the rear of the output connectors using piercing probes. These probes interface with the back of the cable connector that connects to the load, ensuring voltage is measured as close to the load input as possible. Measurements are logged every second during the 15 minute steady-state period for each load condition.

Where do you measure the input voltage?

The input voltage measurement is taken as closely as possible to the unit's input connector. A C19 and C14 extractable cable is tailored for common input connectors to achieve this. This specialized input power cable is equipped with voltage measurement leads affixed to the input voltage wires within one-and-a-half-inch proximity to the unit's input power mating connector, as shown in Figure 1 and Figure 2.

Figure 1: C19 Open Connector